CIM / U2100 0F
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Intermittent actuation of the following functions:
Start
Central Locking
Instruments
Air Condition Control
Radio
	
General Bus Fault.
Fault symptom
Intermittent actuation of the following functions:
Start
Central Locking
Instruments
Air Condition Control
Radio
On-board diagnosis
Type of diagnosis:
Enable criteria:
| Voltage is over 9V but under 16V | 
Fault criteria:
| The cause of the fault is a short circuit of the I-bus anywhere in the connecting wiring harness or internally in a connecting control module. | 
System reaction to a fault:
Checking the wiring harness
| • | Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force. | 
| • | Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force. | 
Diagnostic help
If the DTC is stored and read with the diagnostic instrument, it indicates intermittent bus lead fault.