SAAB WIS ONLINE

PSG16 / P0652 03

Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general) Idling speed set to 1400 rpm. Rpm cannot be controlled. Performance loss.

  P0652 03


Voltage Supply Group 2. Short to Ground.

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

Idling speed set to 1400 rpm.

Rpm cannot be controlled.

Performance loss.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Voltage is lower than 4,6 V for more than 0,2 s.

System reaction to a fault:

Limp Home, engine torque limitation.
The control module uses a substitute value for air mass of 800 mg/combustion and an atmospheric pressure of 70 kPa.

OK report:

Fault criteria NOT fulfilled for 0.2 s.

Checking the wiring harness

Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force.
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards: