Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general) Performance loss.

  P2102 02


Throttle Valve Actuator Circuit , Short to Ground

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

Performance loss.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Output short circuit to ground for more than 0.6 s.

System reaction to a fault:

Limp Home, engine torque limitation.
Control module uses 100% PWM signal as substitute value for EGR control.
Shut-off damper, motor not working.
The control module uses 0% PWM signal as substitute value for the shut-off flap control valve.

OK report:

Fault criteria NOT fulfilled for 0.6 s.

Checking the wiring harness

Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force.
Jiggle the wiring harness at several points to detect intermittent breaks or short circuits. Check also the connector for oxidation or loose pins.

Diagnostic help

EGR turned off in case of fault.