T8 / P0532 00
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: No cooling.
No A/C function.
	
A/C Pressure Sensor Circuit, Open/Short to Ground

Fault symptom
No cooling.
No A/C function.
On-board diagnosis
Type of diagnosis:
Enable criteria:
| Battery voltage must be between 11 - 16 V. | 
| Outdoor temperature higher than -7°C. | 
Fault criteria:
| When input voltage is below 0.25 V for more than 1 s. | 
Dependent:
System reaction to a fault:
| The control module deactivates the output to the A/C relay. | 
OK report:
| Fault criteria NOT fulfilled for 2 s. | 
Fault handling:
| Type III without Check Engine. | 
| (See section Fault handling III, "Other emission-related components and functions" for more information.) | 
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. | 
Functions in the diagnostic tool related to the fault:
| (See also description of readings/activations in diagnostic tool) |