T8 / P0628 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Engine does not start.
Fuel Pump Relay Circuit, Short to Ground
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Engine does not start.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Battery voltage must be between 11 - 16 V. |
Fault criteria:
When voltage on the output is below 2.0 V for more than 1 s. |
Dependent:
System reaction to a fault:
OK report:
Fault criteria NOT fulfilled for 2 s with engine running. |
Fault handling:
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Fault in connector H42-2 is often a cause of this DTC. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |