T8 / P1606 00
Read the instructions below then 
start the fault diagnostic procedure.
	
Control Module. Internal Fault

On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
| Control module on-board diagnostics has detected a fault in the main processor. | 
Dependent:
OK report:
| Fault criterion not fulfilled and vehicle speed over 0 km/h for more than 60 s. | 
Fault handling:
| Type III without Check Engine. | 
| (See section Fault handling III, "Other emission-related components and functions" for more information.) | 
Diagnostic help
Diagnosis regards:
| To locate electrical faults in the control module internal electronics. | 
| See "Before changing a control module" and "After fitting a control module" under Fault diagnosis, general. | 
Functions in the diagnostic tool related to the fault:
| See menu "All - Add/Remove" |