SAAB WIS ONLINE

T8 / P1680 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general) Limp home

  P1680 00


Control Module. Internal Fault

Fault symptom

Fault indicator lamp (for further information see WIS Fault diagnosis, general)

Limp home

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

When pedal position in the main processor and MCP processor are not the same.

Dependent:

None

System reaction to a fault:

Limp home

OK report:

Fault criterion not fulfilled and vehicle speed over 0 km/h for more than 60 s.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Diagnostic help

Diagnosis regards:

To locate electrical faults in the control module internal electronics.
____________________________________
IMPORTANT
If the control module part number is 55354002 for B202E/L or 55354562 for B207R, the module should be updated to the latest software since these parts can incorrectly generate a DTC. If the part number is later than the numbers indicated, perform the normal fault diagnosis. The DTC can remain after SPS programming if the fault is genuine.

____________________________________
See "Before changing a control module" and "After fitting a control module" under Fault diagnosis, general.

Functions in the diagnostic tool related to the fault:

See menu "All - Add/Remove"