SAAB WIS ONLINE

Test readings, control module connections, SID

Test readings, control module connections, SID




Scope

Values and instructions for measuring SID unit voltage levels are found under each section heading.

Remember:


Note the test conditions and use common sense when assessing test results.

The test readings presented are with the ignition in position ON unless otherwise specified.

First check that the control module has a power supply and is grounded.

Then check all sensor inputs and signals from other systems.

Lastly, check the control module outputs. Remember, the readings do not say anything about whether or not the actuator is in working order.

If any reading is not OK, consult the wiring diagram to trace the leads, connectors or components which should be checked more thoroughly.

The specified test readings refer to those obtained with a calibrated Fluke 88/97.

Test readings % (+) and ms (+) show the signal's pulse ratio and pulse width. A test instrument with pulse ratio and pulse width measurement must be used. The sign (+) indicates a positive trigger pulse, TRIG+.




>= greater than; <= less than; ~= alternating current

A pin with no additional comments has no pin connection (LP: LOGIC PROBE P= select pulse; p= visible pulses)

Pin No. Cable colour Component/function In/Out Test conditions Across Test reading See
20 BU/RD Parking heater / Auxiliary heater Out Activated 20-1 0 V
Not activated 20-1 B+