Pressure sensor, A/C (620) PSG16
|
Pressure sensor, A/C (620) PSG16
|
Pressure sensor, A/C (620)
The value is used by ECM for load compensation based on the A/C compressor's load on the engine. Also used for radiator fan logic and block conditions (pressure monitor) in the A/C system.
The pressure sensor contains two metal plated ceramic discs mounted in close proximity. The disc located closest to the pressure connection is thinner and bends when subjected to pressure. By this means, capacitance between the metal plating of the discs is changed based on the pressure. A circuit integrated in the sensor converts the capacitance to an analogue voltage.
PSG16
Pin No.
|
Signal type
|
Description
|
A
|
Ground
|
Connected to ECM pin 8(K).
|
B
|
Power supply, 5 V
|
Connected to ECM pin 31(K).
|
C
|
Signal
|
Connected to ECM pin 52(K).
|