Valve housing
Valve housing |
To remove |
Important | ||
Automatic transmission up to and including 02GV 706486 : The wiring harness must also be changed when changing the valve housing so it suits the new one. |
||
1. |
Remove the
Valve housing cover
|
2. |
Detach the solenoid electrical connections and the temperature sensor.
|
3. |
Undo the marked bolts with 10 mm heads which secure the valve housing.
|
4. |
Carefully detach the manual valve from the selector lever out of the attachment lug and carefully remove the valve housing downward.
|
5. |
Replace the O-rings if necessary.
|
To fit |
Important | ||
Automatic transmission up to and including 02GV 706486 : The wiring harness must also be changed when changing the valve housing so it suits the new one. |
||
1. |
Fit the O-rings. Fit the valve housing in position.
|
2. |
Fit the valve housing.
Tightening torque 7 Nm (5 lbf ft)
|
3. |
Connect the solenoid electrical cables and fit the temperature sensor.
|
4. |
Fit the
Valve housing cover
.
|
5. |
After valve housing replacement, carry out
Adaptation, resetting.
|