SAAB WIS ONLINE

Gear selector control module (726)

Gear selector control module (726)

Location

Gear selector control module (726)


Main use

To convey information to TCM if shifting up or down is done in gear position "M".

To inform Ignition switch module that gear position "P" has been selected.

To indicate with LEDs in the gear selector coulisse the gear position that is currently selected, P-R-N-D or M.

Type

Microprocessor with integrated Hall sensor.

Activation

The SLM control module is powered with +30 on pin 2 from main fuse box 22, fuse 5. Grounding takes place on pin 3, grounding point G41. Bus communication (I-bus) takes place on pin 12. Communication regarding up or down shifting in position "M" takes place from pin 7 on SLM to pin 8 (A) on TCM.


Pin no. Interface Description
2 + 30 Supply from main fuse box 22
3 ground grounding point G41
12 Bus I-bus
7 Up and down shifting to pin 8 (A) on TCM



Power supply, ground and bus connection


Communication with TCM