Draining and filling the refrigerant
 
  
 
 
  
   
    
     |  | Draining and filling the refrigerant | 
   
  
  
   
   
   
   
    
     
      
       | 
         
          
           | 
             
              
               |  Warning |  
               | 
                 
                  
                   | 
                     Read through the following safety regulations before you start working on the A/C system.
                     |  
                   | • | Wear protective glasses and impermeable gloves, since there is a risk of burn and frost injuries. 
 
 |  
                   | • | If the skin comes into contact with the refrigerant, the exposed areas should be bathed in cold water and treated like a burn. 
 
 |  
                   | • | Should the coolant get into the eyes, they must be rinsed thoroughly with water for at least 10 minutes. 
 
 |  
                   | • | Refrigerant must not intentionally be released into the atmosphere. If, however, the refrigerant is unintentionally released in the premises, open and ventilate well before continuing work. 
 
 |  
                   | • | Gases that are formed when heating a refrigerant are a health hazard and can have a serious effect on the lungs. 
 
 |  
                   | • | Work should commence as soon as possible after emptying the A/C system as residual oil may emit refrigerant vapour that could collect and leak out if the work is delayed. 
 
 |  
                   | • | Smoking and open flames must not occur when handling refrigerants. 
 
 |  
                   | • | Refrigerant containers must not be exposed to heating, because the pressure will then increase resulting in the risk of explosion. 
 
 |  |  
               |  |  |  | 
     
    
    
   
   
    For information on the actual equipment, please refer to the manual of the equipment in question.
    
    
    
    
    
    
    
   
   
    
   
   
   
    
     
      
       | 1. | Remove the protective covers from the high and low-pressure pipes. 
 
 | 
     
    
   
   
    
     
      
       | 2. | Attach the blue hose to the low-pressure pipe. Connect the red hose to the high-pressure pipe. 
 
 | 
     
    
   
   
    
     
      
       | 3. | The quick couplings are designed as so-called Schrader valves. Connection is therefore done in two steps: 
 
 | 
     
    
   
   
    
     
      
       |  | • | Fit the quick coupling to the service connection. 
 
 | 
     
    
   
   
    
     
      
       |  | • | Turn the handle clockwise, so that the valve opens and the refrigerant can pass through the connection. 
 
 | 
     
    
   
   
    
     
      
       | 4. | Begin draining the system. Follow the instructions for the machine in question. Note the amount of compressor oil drained. 
 
 | 
     
    
   
   
    
     
      
       | 5. | Close the cocks and disconnect the machine. 
 
 | 
     
    
   
   
    
     
      
       | 6. | Fit the protective covers to the high and low-pressure pipes. 
 
 | 
     
    
   
   
   
   
   
   
   
   
    
   
   
   
    
     
      
       | 1. | Remove the protective covers from the high and low-pressure pipes. 
 
 | 
     
    
   
   
    
     
      
       | 2. | Attach the blue hose to the low-pressure pipe. Connect the red hose to the high-pressure pipe. 
 
 | 
     
    
   
   
    
     
      
       | 3. | The quick couplings are designed as so-called Schrader valves. Connection is therefore done in two steps: 
 
 | 
     
    
   
   
    
     
      
       |  | • | Fit the quick coupling to the service connection. 
 
 | 
     
    
   
   
    
     
      
       |  | • | Turn the handle clockwise, so that the valve opens and the refrigerant can pass through the connection. 
 
 | 
     
    
   
   
    
   
   
    
     
      
       | 5. | For fully automatic filling
        
        : Fill with compressor oil and tracing agent as described in the machine's instructions. 
 
 | 
     
    
   
   
    
     
      
       | 6. | Begin filling the systems. Follow the instructions for the machine. 
 
 | 
     
    
   
   
    
     
      
       | 7. | Close the cocks and disconnect the machine. 
 
 | 
     
    
   
   
    
     
      
       | 8. | Fit the service valves on the high-pressure and low-pressure pipes. 
 
 |