EHPS / C1512 54
Read the instructions below then start the fault diagnostic procedure.
| C1512 54 |
Internal Control Module Malfunction
On-board diagnosis
Type of diagnosis:
| Continuous |
Enable criteria:
| Ignition ON. |
Fault criteria:
| Control module temperature greater than 120°C for more than 0.1 seconds. |
Diagnostic help
Diagnosis regards:
| The diagnostic trouble code can be generated if the system is overloaded (for example, during several parking manoeuvres at high outside temperatures). |