PSG16 / P0112 02
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Intake Air Temperature Sensor Circuit. Short to Ground.
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
When voltage on input below 0.18V for more than 0.6 s. |
Dependent:
System reaction to a fault:
Control module uses 50 degrees C as substitute value. |
OK report:
Input conditions fulfilled without a fault reported. |
Checking the wiring harness
• | Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force. |
• | Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force. |
Diagnostic help
The sensor is a combined temperature and pressure sensor.