PSG16 / P2100 04
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Performance loss.
Throttle Valve Actuator Circuit, Open
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Performance loss.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
No voltage on the control module output for more than 0.6 s |
System reaction to a fault:
Control module uses 100% PWM signal as substitute value for EGR control. |
Shut-off damper, motor not working. |
The control module uses 0% PWM signal as substitute value for the shut-off flap control valve. |
OK report:
Fault criteria NOT fulfilled for 0.6 s. |
Checking the wiring harness
• | Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force. |
• | Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force. |
Diagnostic help
EGR turned off in case of fault.