SPA  / B0958 06

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display. SPA stops all measurements and the acoustic signals from SID for SPA are switched off.

  B0958 06


Left Outer Distance Sensor. Communication line is open or short to ground.

Fault symptom

Message appears in display.
SPA stops all measurements and the acoustic signals from SID for SPA are switched off.

On-board diagnosis

Type of diagnosis:


Enable criteria:

Ignition ON.
Reverse gear selected
Battery voltage greater than 9 V.

The following diagnostic trouble codes may not be generated:
B1350 01
B1350 02

Fault criteria:


Signal Lines(s) Shorted to Ground

System reaction to a fault:

The control module is inactive until it receives a signal from the sensor.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

See Reading:
Distance, Left Outer Sensor
(See also description of readings/activations in diagnostic tool)