SAAB WIS ONLINE

T8 / P0647 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: A/C not working, no cooling.

  P0647 00


A/C relay, short circuit to B+

Fault symptom

A/C not working, no cooling.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 11 - 16 V.
Ignition ON or Engine running.
A/C requested.
Output is active.

Fault criteria:

When voltage on the output exceeds 2.0 V for more than 1 s.

Dependent:

None

System reaction to a fault:

Output to the A/C relay is switched off.

OK report:

Fault criteria NOT fulfilled for 2 s.

Fault handling:

Type III without Check Engine.
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activation:
AC Relay

(See also description of readings/activations in diagnostic tool)