SAAB WIS ONLINE

TCM / P1712 71

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display.

  P1712 71


Wheel Speed FR. Bus Data Unreliable

Fault symptom

Message appears in display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition on for at least 3 s.
Exceptions:
TCM in Limp Home.

Fault criteria:

Control module receives faulty signal from wheel sensor.

System reaction to a fault:

Limp home