SAAB WIS ONLINE

UEC / B3869 02

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display. Front right side direction indicator malfunction.

  B3869 02


Turn Indicator Repeater Left Front Circuit, Short to Ground

Fault symptom

Message appears in display.

Front right side direction indicator malfunction.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Right direction indicators on.

Fault criteria:

Current consumption is over 3.5 A for more than 10 ms.

System reaction to a fault:

Control module output is switched off.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Activation:
Turn Indicator Repeater Right Fr.
(See also description of readings/activations in diagnostic tool)