Xenon lamp ballast (663b)
Xenon lamp ballast (663b) |
Main task |
The ballast ensures that the lamp is subjected to the correct working conditions as regards current and voltage. The ballast generates running voltage in a DC/AC converter, where 12 V DC is converted to approx. 85 V AC at a frequency of about 300 Hz.
Type |
Ballast for Xenon lamp of type D2S.
Connection |
The ballast (663b) is connected to the ignition transformer (663a).
The ballast is supplied voltage from headlamp pin 3 and is grounded in headlamp pin 1.
Power supply and ground, left (US/CA)
Power supply and ground, left (others)
Power supply and ground, right (US/CA)
Power supply and ground, right (others)