SAAB WIS ONLINE

AHL / B3440 02

Read the instructions below then start the fault diagnostic procedure.

Symptom: Message appears in display. Headlamp beam adjustment not working.

  B3440 02


RH Stepper Motor Circuit, Short to Ground

Fault symptom

Message appears in display.

Headlamp beam adjustment not working.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
Xenon lights on.
Stepping motor activated.
Battery voltage greater than 9 V.

Fault criteria:

Control module output short-circuit to ground.

System reaction to a fault:

Control module outputs to stepping motor switched off.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Before fault diagnosis begins, read the document "Safety and handling directions, xenon lights" under Technical description.