CIM / C0547 01
Read the instructions below then 
start the fault diagnostic procedure.
Symptom: Cannot turn key.
Message appears in display.
Engine does not start.
	
SCL-ISM, Unlocked & Secured Circuit, Short to B+

 
Fault symptom
Cannot turn key.
Message appears in display.
Engine does not start.
On-board diagnosis
Type of diagnosis:
Enable criteria:
| Diagnostics runs when key is inserted. | 
Fault criteria:
| ISM-SCL lead short circuited to B+ | 
System reaction to a fault:
| The control module does not allow starter motor cranking. | 
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
| Electrical fault in connecting leads or component. | 
Functions in the diagnostic tool related to the fault:
| SCL Voltage, Unlocked and Secured | 
| Key Capture. Steering Unlocked and Secured | 
| (See also description of readings/activations in diagnostic tool) |