Simtec radiator fan relay unit, change
 
  
 
 
  
   
    
     | 
      | 
     
      Simtec radiator fan relay unit, change
      | 
    
   
  
  
   
   
   
   
   
    
   
   
    
     
      
       | 
        2.
        | 
       
        Disconnect the battery.
         
         
        
         Remove the ground cable.
         
        | 
      
     
    
   
   
    
     
      
       | 
        3.
        | 
       
        Pull off the cable set connector to the relay unit (1)
         
         
        
         Remove the cable set
         
        
          
        
         
        | 
      
     
    
   
   
    
     
      
       | 
        4.
        | 
       
        Remove the relay unit (1)
         
         
        
         Pull off the fan motor cable set connector (2)
         
        
         Undo the bolt (arrow)
         
        
          
        
         
        | 
      
     
    
   
   
    
     
      
       | 
        5.
        | 
       
        Fit the relay unit
         
         
        
         Tighten the bolt - Tightening torque 2 Nm
         
        
         Fasten the fan motor cable set connector
         
        | 
      
     
    
   
   
    
     
      
       | 
        6.
        | 
       
        Connect the cable set connector for the relay unit
         
         
        
         Fit the cable set
         
        | 
      
     
    
   
   
    
     
      
       | 
        7.
        | 
       
        Connect the battery.
         
         
        
         Fit the ground cable.
         
        | 
      
     
    
   
   
    
     
      
       | 
        8.
        | 
       
        Program erased memories
         
         
        |