Test readings, rear right door module, (702RR)
 
  
 
 
  
   
    
     | 
      | 
     
      Test readings, rear right door module, (702RR)
      | 
    
   
  
  
  
   
  
  
  
   The following pages contain directions and readings for testing signals and levels of the control module.
   
   
   
   
   
   
   
  
  
   
  
  
  
   
    
     
      | 
       •
       | 
      
       Observe the test criteria. Use common sense when assessing the test results.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       Check first that the control module is receiving power and is grounded.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       Then check all sensor inputs and signals from other systems.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       Finally, check the control module outputs. Remember that the test readings are not a confirmation of whether the actuator is in working order.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       If a test reading is incorrect, use the wiring diagram to locate the leads, connectors or components that need to be checked further.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       Specified readings are for a calibrated Fluke 88/97.
        
        
       | 
     
    
   
  
  
   
    
     
      | 
       •
       | 
      
       Test readings % (+) and ms (+) indicate the signal pulse ratio and pulse width respectively. A scan tool with pulse ratio and pulse width measurement must be used. The sign indicates positive trigger pulse, TRIG+.
        
        
       | 
     
    
   
  
  
  
  
  
  
  
  
   
   
    
   
   
  
  
   
    
     
      | 
       Note
       | 
     
     
      | 
        
        All units on the I and P-buses send signals.
        
       | 
     
    
   
   
   
    
     
     
     
     
     
     
     
    
    
     
      | 
       
        
         Control module pin
        
       
       | 
      
       
        
         Component/
        
       
       
        
         function
        
       
       | 
      
       
        
         IN/OUT
        
       
       | 
      
       
        
         Test criteria
        
       
       | 
      
       | 
      
       
        
         Measure across
        
       
       | 
      
       
        
         Test reading
        
       
       | 
     
     
      | 
       
        1-3
       
       | 
      
       
        Not connected
       
       
       
       | 
      
       
       
       | 
      
       
       
       | 
      
       
       
       | 
      
       
       
       | 
      
       | 
     
     
      | 
       
        4
       
       | 
      
       
        Ground, logic
       
       | 
      
       
        OUT
       
       | 
      
       
        Ignition ON
       
       | 
      
       
       
       | 
      
       
        4-B+
       
       | 
      
       
        B+
       
       | 
     
     
      | 
       
        5
       
       | 
      
       
        Power supply, hall sensor
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       | 
      
       
        6-(J2-7)
       
       | 
      
       
        4.6-4.7V
       
       | 
     
     
      | 
       
        6-8
       
       | 
      
       
        Not connected
       
       
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        9
       
       | 
      
       
        Hall sensor 2
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       
        Express activated
       
       | 
      
       
        9-5
       
       | 
      
       
        6.3-6.4 AC
       
       | 
     
     
      | 
       
        10-12
       
       | 
      
       
        Not connected
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        13
       
       | 
      
       
        TSL sensor
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       
       
       | 
      
       
        13-(J2-7)
       
       | 
      
       
        11V
       
       | 
     
     
      | 
       
        14
       
       | 
      
       
        Sensor, central locking system lock/unlock
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       
       
       | 
      
       
        14-(J2-7)
       
       | 
      
       
        1.86V
       
       | 
     
     
      | 
       
        15
       
       | 
      
       
        Not connected
       
       
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        16
       
       | 
      
       
        Hall sensor 1
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       
        Express activated
       
       | 
      
       
        16-5
       
       | 
      
       
        6.3-6.4 AC
       
       | 
     
     
      | 
       
        17-18
       
       | 
      
       
        Not connected
       
       | 
      
       | 
      
       | 
      
       | 
      
       
       
       | 
      
       | 
     
     
      | 
       
        19
       
       | 
      
       
        Central locking system, lock/unlock
       
       | 
      
       
        OUT
       
       | 
      
       
        Door closed, ignition OFF
       
       | 
      
       
       
       | 
      
       
        19-(J2-7)
       
       | 
      
       
        Lock 12V for <0.2s
       
       
        Unlock 4.5V for <0.2s
       
       | 
     
     
      | 
       
        20
       
       | 
      
       
        +30 voltage logic
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       
       
       | 
      
       
        20-(J2-7)
       
       | 
      
       
        B+
       
       | 
     
     
      | 
       
        21
       
       | 
      
       
        Not connected
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        22
       
       | 
      
       
        Ground, hall sensor
       
       | 
      
       
        OUT
       
       | 
      
       | 
      
       | 
      
       
        22-5
       
       | 
      
       
        4.76V
       
       | 
     
     
      | 
       
        23
       
       | 
      
       
        Central locking system, lock/unlock
       
       | 
      
       
        OUT
       
       | 
      
       
        Door closed, ignition OFF
       
       | 
      
       
        Door closed, lock
       
       | 
      
       
        23-(J2-7)
       
       | 
      
       
        Lock 0.3V for <0.2s
       
       
        Unlock 12V for <0.2s
       
       | 
     
     
      | 
       
        24
       
       | 
      
       
        Sensor ground, central locking system
       
       | 
      
       
        OUT
       
       | 
      
       
        Ignition ON
       
       | 
      
       | 
      
       
        24-32
       
       | 
      
       
        4.10V
       
       | 
     
     
      | 
       
        25
       
       | 
      
       
        TSL activation
       
       | 
      
       
        OUT
       
       | 
      
       
        Door closed, ignition OFF
       
       | 
      
       | 
      
       
       
       | 
      
       
        Lock 6V for <0.2s
       
       
        Unlock 5.2V for <0.2s
       
       | 
     
     
      | 
       
        26-27
       
       | 
      
       
        Not connected
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        27
       
       | 
      
       
        Courtesy lighting
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       | 
      
       
        27-(J2-7)
       
       | 
      
       
        B+
       
       | 
     
     
      | 
       
        28
       
       | 
      
       
        I-bus
       
       | 
      
       
        OUT
       
       | 
      
       
        Ignition ON
       
       | 
      
       
        Use
        
         86 11 857 Test lamp, red/green
        
       
       | 
      
       
        28-(J2-7)
       
       | 
      
       
        Test lamp should flash
       
       | 
     
     
      | 
       
        29-31
       
       | 
      
       
        Not connected
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        32
       
       | 
      
       
        Door switch
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       | 
      
       
        32-(J2-7)
       
       | 
      
       
        4.10V
       
       | 
     
    
   
   
   
   
   
   
   
   
  
  
   
  
  
   
    
     
      | 
       Note
       | 
     
     
      | 
        
        All units on the I and P-buses send signals.
        
       | 
     
    
   
   
   
    
   
   
   
    
     
     
     
     
     
     
     
    
    
     
      | 
       
        
         Control module pin
        
       
       | 
      
       
        
         Component/
        
       
       
        
         function
        
       
       | 
      
       
        
         IN/OUT
        
       
       | 
      
       
        
         Test criteria
        
       
       | 
      
       | 
      
       
        
         Measure across
        
       
       | 
      
       
        
         Test reading
        
       
       | 
     
     
      | 
       
        1
       
       | 
      
       
        Window lift, up
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       
        Close window
       
       | 
      
       
        1-7
       
       | 
      
       
        B+
       
       | 
     
     
      | 
       
        2
       
       | 
      
       
        Not connected
       
       | 
      
       
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        3
       
       | 
      
       
        +30 voltage
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       
       
       | 
      
       
        3-7
       
       | 
      
       
        B+
       
       | 
     
     
      | 
       
        4
       
       | 
      
       
        Not connected
       
       | 
      
       
       
       | 
      
       
       
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        5
       
       | 
      
       
        Window lift, down
       
       | 
      
       
        IN
       
       | 
      
       
        Ignition ON
       
       | 
      
       
        Open window
       
       | 
      
       
        5-7
       
       | 
      
       
        B+
       
       | 
     
     
      | 
       
        6
       
       | 
      
       
        Not connected
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
      
       | 
     
     
      | 
       
        7
       
       | 
      
       
        Ground
       
       | 
      
       
        OUT
       
       | 
      
       
        Ignition ON
       
       | 
      
       | 
      
       
        7-3
       
       | 
      
       
        B+
       
       | 
     
     
      | 
       
        8
       
       | 
      
       
        Not connected
       
       | 
      
       | 
      
       | 
      
       | 
      
       | 
      
       |