Position sensor, soft top cover locked (562LH/RH)
| Position sensor, soft top cover locked (562LH/RH) | 
| To remove | 
Only the method for changing the position sensor on the right-hand side is described below. The same method applies to changing the sensor on the left-hand side.
| 1. | 
        Open the soft top cover. Raise the sixth bow and support it with
        
         82 93 847 Soft top support
        
        .
         
        
         | 
      |
| 2. | 
        Remove the cable tie on the position sensor cable. Note the location of the cable ties.
         
        
         | 
      |
| 3. | 
        Unplug the position sensor cable.
         | 
      |
| 4. | 
        Remove the position sensor from the soft top cover hinge using a screwdriver.
         | 
      |
| 5. | 
        Remove the position sensor from the plastic holder.
         
        
         | 
      |
| To fit | 
| 1. | 
        Fit the position sensor to the plastic holder.
         
        
         | 
      |
| 2. | 
        Fit the position sensor to the soft top cover hinge.
         
        
         | 
      |
| 3. | 
        Connect the position sensor cable connector.
         | 
      |
| 4. | 
        Fit the cable tie to the position sensor.
        
  | 
      ||||||||||
| 5. | 
        Remove the soft top support and raise the soft top.
         | 
      |
| 6. | 
        Test the operation of the soft top.
         | 
      |
| 7. | 
        Connect the diagnostics tool and erase any diagnostic trouble code.
         | 
      |