SAAB WIS ONLINE

ACC / B0165 02

Read the instructions below then start the fault diagnostic procedure.

  B0165 02


Compartment Temperature Sensor Circuit, Short to Ground



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Voltage on control module sensor input is below 0.2 V.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Compartment Temperature Sensor
(See also description of readings/activations in diagnostic tool)