ACC / B0240 06
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Incorrect air distribution.
Defrost Door Motor Circuit, Open/Short to Ground
Fault symptom
Incorrect air distribution.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Air distribution motor activated. |
Fault criteria:
Break or short-circuit to ground in the circuit of the air distribution damper motor. |
System reaction to a fault:
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
Air distribution damper, defrost. |
(See also description of readings/activations in diagnostic tool) |