ACC / B0511 02
Read the instructions below then
start the fault diagnostic procedure.
Air Mix Temperature Sensor Right Vent Circuit, Short to Ground
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
Voltage on control module sensor input is below 0.2 V. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
In the event of faults, the control module uses the value from the mixed-air temperature sensor, RH floor.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
Air Mix Temperature Sensor Right Vent |
Air Mix Temperature Right Vent |
Air Mix Temperature Sensor Right Floor |
Air Mix Temperature Right Floor |
(See also description of readings/activations in diagnostic tool) |