SAAB WIS ONLINE

ACC / B0517 05

Read the instructions below then start the fault diagnostic procedure.

  B0517 05


Air Mix Temperature Sensor Right Floor Circuit, Open/Short to B+



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Voltage on control module sensor input exceeds 4.8 V.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

In the event of faults, the control module uses the value from the mixed-air temperature sensor, RH panel.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Read value:
Air Mix Temperature Right Floor
Air Mix Temperature Sensor Right Floor
Air Mix Temperature Right Vent
Air Mix Temperature Sensor Right Vent
(See also description of readings/activations in diagnostic tool)