SAAB WIS ONLINE

ACC / B0521 02

Read the instructions below then start the fault diagnostic procedure.

  B0521 02


Evaporator Temperature Sensor Circuit, Short to Ground



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Voltage on control module sensor input is below 0.2 V.

System reaction to a fault:

The control module uses outside temperature as a substitute value.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Evaporator Temperature Sensor