AHM/PHM / B0443 01
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Poor cabin heating
Heater does not start.
Fuel Pump Circuit, Short to B+
Fault symptom
Poor cabin heating
Heater does not start.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fuel pump heater inactive |
Fault criteria:
Control module output to heater fuel pump shorted to B+ for more than 1.3 s. |
OK report:
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |