SAAB WIS ONLINE

AHM/PHM / B1000 37

Read the instructions below then start the fault diagnostic procedure.

Symptom: Poor cabin heating Heater does not start.

  B1000 37


Control Module. Internal Fault

Fault symptom

Poor cabin heating

Heater does not start.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
Heater not in rest mode.

Fault criteria:

Control module on-board diagnostics has detected a "Timeout" fault.

System reaction to a fault:

Heater is switched off.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

See "Before changing a control module" and "After fitting a control module" under Fault diagnosis, general.