SAAB WIS ONLINE

BCM / B1448 01

Read the instructions below then start the fault diagnostic procedure.

  B1448 01


+X-Relay Circuit, Short to B+



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

Current exceeds 400 mA.

System reaction to a fault:

Control module output turned off for 2 seconds.

OK report:

Fault criteria NOT fulfilled.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.