Read the instructions below then start the fault diagnostic procedure.

Symptom: Interior lighting malfunction.

  B2610 02


Interior Light PWM Circuit, Short to Ground

Fault symptom

Interior lighting malfunction.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
Interior lighting button OFF.

Fault criteria:

When voltage on the input is below 2.0 V.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Interior Light, PWM
Activate:
Interior Light, PWM
(See also description of readings/activations in diagnostic tool)