SAAB WIS ONLINE

CIM / B1368 0F

Read the instructions below then start the fault diagnostic procedure.

Symptom: Steering column lock not working.

  B1368 0F


+B Circuit, Short to B+

Fault symptom

Steering column lock not working.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Starter motor cranking.

Fault criteria:

Control module input short circuit to B+.

System reaction to a fault:

Steering column lock deactivated.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Ignition Switch +B, K-Line from ISM
(See also description of readings/activations in diagnostic tool)