CIM / C0490 06
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Message appears in display.
Steering column lock not working.
Possible that ignition key cannot be turned.
ISM-SCL, Unsecure Lockingbolt Circuit, Open/Short to Ground
Fault symptom
Message appears in display.
Steering column lock not working.
Possible that ignition key cannot be turned.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Diagnostics runs when key is removed. |
Fault criteria:
Lead ISM-SCL shorted to ground/open-circuit. |
System reaction to a fault:
Steering column lock deactivated. |
The control module does not allow starter motor cranking. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
SCL Voltage, Unlocked and Secured |
(See also description of readings/activations in diagnostic tool) |
ISM-SCL, Unsecure Lockingbolt Circuit, Open/Short to Ground
|