CIM / C0547 02
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Message appears in display.
Engine does not start.
SCL-ISM, Unlocked & Secured Circuit, Short to Ground
Fault symptom
Message appears in display.
Engine does not start.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Diagnostics runs when the key is inserted in the ignition switch and is turned to ON again. |
Fault criteria:
ISM-SCL lead, open circuit. |
System reaction to a fault:
The control module does not allow starter motor cranking. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
SCL Voltage, Unlocked and Secured |
Key Capture. Steering Unlocked and Secured |
(See also description of readings/activations in diagnostic tool) |