CU AMPS / B2476 04
Read the instructions below then start the fault diagnostic procedure.
Symptom: "On Star System Malfunction. Contact Service." shown on the display. OnStar buttons not working.
B2476 04 |
Fault symptom
"On Star System Malfunction. Contact Service." shown on the display.OnStar buttons not working.
On-board diagnosis
Type of diagnosis:
Continuous |
Enable criteria:
Ignition ON. |
Battery voltage must be between 9 - 16 V. |
Fault criteria:
Open circuit |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.Diagnostic help
Check that the following MIs/Campaigns have been carried out before starting fault diagnosis:US Market
MI No. 391-2394 - Customer Satisfaction Campaign 15421 - Update of OnStar system.
MI No. 391-2409 - Customer Satisfaction Campaign 15424 - Update of OnStar system.
CA Market
MI No. 391-2410 - Customer Satisfaction Campaign 15421 - Update of OnStar system.
MI No. 391-2408 - Customer Satisfaction Campaign 15424 - Update of OnStar system.