SAAB WIS ONLINE

CU AMPS / U1000 08

Read the instructions below then start the fault diagnostic procedure.

Symptom: "On Star System Malfunction. Contact Service." shown on the display.

  U1000 08


GPS Signal Error

Fault symptom

"On Star System Malfunction. Contact Service." shown on the display.

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.
Battery voltage must be between 9 - 16 V.
No starter motor cranking.

Fault criteria:

A memory error has occurred in the GPS module.

Diagnostic help

Change the control module.

See "Before changing a control module".

Check that the following MIs/Campaigns have been carried out before starting fault diagnosis:

US Market

MI No. 391-2394 - Customer Satisfaction Campaign 15421 - Update of OnStar system.

MI No. 391-2409 - Customer Satisfaction Campaign 15424 - Update of OnStar system.

CA Market

MI No. 391-2410 - Customer Satisfaction Campaign 15421 - Update of OnStar system.

MI No. 391-2408 - Customer Satisfaction Campaign 15424 - Update of OnStar system.

Diagnostic help

Diagnosis regards:

To locate electrical faults in the control module internal electronics.

Functions in the diagnostic tool related to the fault:

See menu "All - Add/Remove"