Read the instructions below then start the fault diagnostic procedure.

Symptom: Side window cannot be closed.

  B3210 06


Power Window Up, Open Circuit/Short to Ground

Fault symptom

Side window cannot be closed.

On-board diagnosis

Type of diagnosis:

Diagnostics run when power window is operated.

Enable criteria:

Ignition ON.

Fault criteria:

Current through the engine is less than the permissible calibrated value

System reaction to a fault:

The motor attempts to raise the window during each new driving cycle.

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Window Motor Driver Door
(See also description of readings/activations in diagnostic tool)