DSM / B1770 0B
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Memory functions not working
Slide Motor Circuit, Current Too High
Fault symptom
Memory functions not working
On-board diagnosis
Type of diagnosis:
Continually when the engine is run. |
Enable criteria:
When seat operation is permitted. |
Fault criteria:
Current consumption is more than 40A +/- 6A. |
System reaction to a fault:
Output is switched off, tries however to activate the engine once each time the ignition is switched on. |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Mechanical check of motor |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |