DSM / B2365 02
Read the instructions below then
start the fault diagnostic procedure.
Symptom: No memory functions work
Seat can jerk during start and stop.
Position Sensor Power Supply Circuit, Short to Ground
Fault symptom
No memory functions work
Seat can jerk during start and stop.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
Output voltage is less than 1.2 ± 0.2V. |
System reaction to a fault:
Memory functions not working |
The control module loses end position calibration for the motor in question. |
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |