EDC16 / P0380 04
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Fault indicator lamp (for further information see WIS Fault diagnosis, general)
Glow Control Unit. Open Circuit.
Fault symptom
Fault indicator lamp (for further information see WIS Fault diagnosis, general)
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
No voltage on the control module output for more than 0.6 s |
OK report:
Fault criteria NOT fulfilled for 0.6 s. |
Checking the wiring harness
• | Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force. |
• | Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force. |
Diagnostic help
Diagnosis regards:
Data link from glow plug control module should switch high/low inversely to activation lead from EDC 16 to glow plug control module. |
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault: