SAAB WIS ONLINE

EDC16 / P0560 11

Read the instructions below then start the fault diagnostic procedure.

  P0560 11


Battery Voltage. Too High.



On-board diagnosis

Fault criteria:

Battery voltage exceeds 17 V.

Diagnostic help

Diagnosis regards:

The DTC can be generated if a 24V battery charger is used to charge the battery or if another vehicle with 24V battery, e.g. a truck, has been used to help start the car.

Functions in the diagnostic tool related to the fault:

Test value:
Battery Voltage
(See also description of readings/activations in diagnostic tool)