EDC16 / P0615 01
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Starter motor malfunction.
Starter Relay Circuit, Short to B+
Fault symptom
Starter motor malfunction.
On-board diagnosis
Type of diagnosis:
Enable criteria:
Fault criteria:
Output short circuit to B+ for more than 0.6 s. |
System reaction to a fault:
Output to the starter motor relay is switched off. |
OK report:
Fault criteria NOT fulfilled for 0.6 s. |
Checking the wiring harness
• | Faults in the control module female connector can be the cause of the DTC. Check the connector with respect to oxidation, depressed pins and pin clamping force. |
• | Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force. |
Diagnostic help
Diagnosis regards:
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |