SAAB WIS ONLINE

ME9 / P0091 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Malfunction Indicator Lamp

  P0091 00


Fuel Pump Module, Control Circuit, Short to Ground

Fault symptom

Malfunction Indicator Lamp

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Motor running more than 5 s.
Fuel pump active.
Tank not empty.

Fault criteria:

When the voltage at the output during ignition is lower than 2.15 V or lower than 2.35 V with the engine running.

OK report:

No fault for 240 seconds.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Fuel Pump Control Signal
Signal from Variable Fuel Pump
Fuel Pressure

Activation:
Fuel Pump Module

(See also description of readings/activations in diagnostic tool)