SAAB WIS ONLINE

ME9 / P0138 00

Read the instructions below then start the fault diagnostic procedure.

  P0138 00


O2S 2 Circuit, High Voltage



On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 10 - 18 V.
Engine running.
Exhaust temperature below 800°C.
Sufficiently warm sensor.

Fault criteria:

When input voltage exceeds 1.08 V for more than 5 seconds.

OK report:

Fault criteria NOT fulfilled.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
O2S 2
Closed Loop
Closed loop lambda control status
Total Fuel Trim

(See also description of readings/activations in diagnostic tool)