SAAB WIS ONLINE

ME9 / P0192 00

Read the instructions below then start the fault diagnostic procedure.

Symptom: Malfunction Indicator Lamp

  P0192 00


Fuel Rail Pressure Sensor Circuit, Low Voltage/Pressure

Fault symptom

Malfunction Indicator Lamp

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Ignition ON.

Fault criteria:

When input voltage is below 0.2 V for more than 0.5 seconds.

Dependent:

None

OK report:

Fault criteria NOT fulfilled.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Jiggle the wiring harness at several points to detect intermittent breaks or short circuits. Check also the connector for oxidation or loose pins.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Fuel Pressure

(See also description of readings/activations in diagnostic tool)