ME9 / P0458 00
Read the instructions below then
start the fault diagnostic procedure.
Symptom: Malfunction Indicator Lamp
EVAP Purge Valve Circuit, Short to Ground
Fault symptom
Malfunction Indicator Lamp
On-board diagnosis
Type of diagnosis:
Enable criteria:
Battery voltage must be between 10 - 18 V. |
EVAP valve activated/deactivated once. |
Fault criteria:
When output voltage is less than 2.6 V when the output is active. |
OK report:
When the PWM signal on the output is between 2% and 80%. |
Fault handling:
(See section Fault handling III, "Other emission-related components and functions" for more information.) |
Checking the wiring harness
Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.
Diagnostic help
Diagnosis regards:
Electrical fault in connecting leads or component. |
Functions in the diagnostic tool related to the fault:
(See also description of readings/activations in diagnostic tool) |