  P0499 00


Canister Close Valve Circuit. Short to B+.

Fault symptom

Malfunction Indicator Lamp

On-board diagnosis

Type of diagnosis:

Continuous

Enable criteria:

Battery voltage must be between 10 - 18 V.
Engine running.
Cut-off valve activated/deactivated once.

Fault criteria:

When output voltage is more than 4.6 V when the output is active.

Fault handling:

Type III
(See section Fault handling III, "Other emission-related components and functions" for more information.)

Checking the wiring harness

Move the wiring harness at several spots and in several directions to reveal intermittent breaks and short-circuits. Check switches, connectors and crimp connections for oxidation, retracted pins and pin clamping force.

Diagnostic help

Diagnosis regards:

Electrical fault in connecting leads or component.

Functions in the diagnostic tool related to the fault:

Test value:
Shut-off valve, EVAP canister.

Activation:
Shut-off valve, EVAP canister.